Mighty Mark-N-Mender Instructions

Mighty Mark-N-Mender
800 WATTS · 8 AMPS · 60 CYCLE · 110V · AC

model-2HHModel # 2-HH

Serial #
Instructions
The machine’s temperature is pre-set for 400 degrees on both the top and bottom heating heads.  The machine is used for the application of transfers, computer label tape, and heat seal patches.  Do not attempt to adjust the temperature unless it has been determined that a different setting is necessary.  Please refer to the maintenance instructions below if an adjustment is required.
The on/off switch is located on the front bottom base of the machine.  A red light on the switch of the front panel will light up when the machine is on.   The temperature gauge is located on the right side of the machine on both the top and bottom heating heads.  Let the machine heat up to temperature before use.  It takes approximately ten to fifteen minutes for the machine to heat up to temperature.

 

The timer is also pre-set and must be used for each application.  Make sure the red handled clamp is snap-locked into position for firm pressure.  When snap-lock is in place it will stay down until you release it when the timer goes off.  Keep the Teflon covers clean at all times.

 

Apply Patches and Mending Tape at 380-400 degrees for 10 seconds.

 

Apply Transfers at 380-400 degrees for 3 seconds.

 

Apply Computer Label Tape at 380-400 degrees for 12-15 seconds.

 

 

Instructions for maintenance department only:

To adjust the top heat: remove top cover by removing two (10-24) screws with washers, located on the top cover.  After the cover is removed, the thermostat is located on the left side of the heating heat.  To increase heat turn the thermostat stem to the right, and to decrease heat turn the thermostat stem to the left.

 

To adjust the bottom heat: remove two self tapping screws located on the sides of the bottom base.  Then remove the bottom insert.  The thermostat is located on the left side.  Turn the thermostat stem to the right to increase the heat or to the left to decrease the heat.

 

The silicone pad and plate is one unit.  The silicone pad can be removed by unscrewing four screws and sliding the unit off.  The Teflon cover can be replaced separately or together with the silicone pad and plate on the bottom heating head.

 
The removal of the Teflon cover and plate on the top heating head is the same as the bottom heating head.  The Teflon cover and plate are two units.  Please refer to the replacement parts list.

 

Over heating the Heat Seal Machine will void the machine’s warranty.